Adding Insulation to a 1944 Roof

first_img GREEN PRODUCT GUIDE RELATED ARTICLES Consider ‘storage capacity’ of the insulationWhile Albert Rooks believes that adding rigid foam is the easiest approach, he offers another thought about the differences between types of insulation that may play a role in lowering summer heat gain.“While lowering the indoor temperature peak on a hot day will obviously lower the indoor temps, increasing the cycle time that it takes to reach the interior peak temp means that the room can stay at comfortable temperatures longer,” Rooks writes. “That is the effect of the insulating materials heat storage capacity.”By choosing insulation with higher storage capacity, he adds, it will take longer for heat to work its way through the roof. The increase in indoor temperatures will still take place, but increasing the cycle time means lower overall heat gain and seeing peak temperatures at 3 a.m. instead of 4 p.m.Dense-pack cellulose and wood fiber insulation boards may have lower R-values per inch, Rooks says, but they have a much higher heat storage capacity than lightweight materials such as rigid foam. Green Basics: Insulating Roofs, Walls and FloorsGreen Basics: Rigid Foam Insulation7 Steps to an Energy-Efficient House: 2. The Roof” Q&A: Heat reflective roofing materialsGreen Basics: Roofing Material Choices RoofingHis plan is to tear off the existing roof down to the 2×4 rafters and then rebuild. The question is how.“Given the extremely limited depth of the rafter bays, I could get a few more R’s using spray foam or rigid foam, but I’m not sure that it would be worth the added expense,” he says. “One roofer has suggested adding pre-fab channels, edge vents and a ridge vent in order to ventilate the roof, but this just cuts the space available for insulation even more.”Cox’s roof project is the subject of this week’s Q&A Spotlight. Thaddeus Cox’s 1944 Cape Cod in Portland, Oregon, has a roof that needs some attention. Not only is the roof under-insulated, but it’s currently covered in two or three layers of asphalt shingles installed over the original layer of cedar. Roof sheathing consists of 1-in. thick boards.The International Energy Conservation Code recommends R-38 for the roof in this Climate Zone 4 house, far more than the R-11 batts Cox thinks are currently in place.But reducing winter heating bills isn’t Cox’s first concern, as he explains in this Q&A post at GreenBuildingAdvisor.“They are already pretty low with our ancient oil furnace, and should be lower after our gas conversion,” Cox writes. “What I’m most interested in is reducing the summer temps in the attic bedroom, presumably by reducing the heat transfer from the sun-heated roof.” RELATED MULTIMEDIA Video: Lstiburek’s Rules for Venting Roofs Beef up the insulationIncreasing the R-value of the roof is an obvious place to start, if only to reduce summer heat gain in the second-floor bedroom. He has more than one option.Even if Cox uses high-density foam, at roughly R-6.5 per inch, the 2×4 rafters will allow only enough insulation to reach R-26 at the most, so some additional depth would be required to reach code minimums. Low-density foam would need an even deeper rafter bay. With that in mind, Jon Schmid suggests furring out existing rafters to create a deeper rafter bay, then adding spray foam insulation.GBA senior editor Martin Holladay would go another route: “Install as much rigid foam on top of the existing sheathing as you can afford,” Holladay writes. “I would suggest at least R-30 of new foam – with or without channels above the foam.”Bob Coleman likes Holladay’s approach. Adding rigid foam on top of the sheathing is “far more economical” than adding spray foam or dense-packed cellulose inside the roof cavity, he says.If Cox wants to vent the new roof, he can build in a space between the rigid foam and new roof deck. Then there’s the roofing itselfHowever Cox chooses to increase the insulation in the roof, he’ll still need to finish the assembly with roof cladding, and this, too, will have something to do with controlling summer heat gain.In his original post, Cox says he was leaning in favor of Energy Star shingles to reduce heat gain, although he wasn’t sure if they were worth the extra expense. Roofing products that carry the Energy Star label have certain solar reflective qualities, and they must have warranties equal to or better than comparable non-reflective products.“Go for an Energy Star metal roof that will help deflect the heat (some lighter colors will almost absorb nothing),” writes Coleman, “then the foam helps seal in the cool generated inside, then a peel-and-stick or other [heavy] duty roof deck covering along with air sealing any gaps prevents conditioned air leakage.”Because they absorb so much heat, dark asphalt shingles are not the best choice in this project, Coleman writes: “If you put a blacktop driveway on your roof, the heat is going to come.”Although Cox isn’t inclined to go with metal, “due to cost, appearance and noise (think rain on a metal roof),” Rooks agrees with Coleman’s suggestion, adding that a metal roof will last much longer than shingles. Our expert’s opinionWe asked GBA technical director Peter Yost for his opinion. Here’s what he says:If the main objective of the new roof assembly is to improve overall thermal performance, but particularly to control summer heat gain, then it is always best to keep the heat out FIRST. Keeping solar heat out, before it becomes a conduction issue, is always the most effective summer heat gain strategy. Reduce the solar gain with a reflective roof cladding and if possible, introduce a ventilated air space underneath the cladding, which will increase convective heat exchange and provide a low-e surface on the backside of the cladding.I don’t think the specific heat capacity per volume of one insulation to another makes a significant difference. The specific heat capacity (per volume) of all insulations is relatively low and there is simply not enough storage in any insulation to match the day-night cycle of heat gain and loss in the roof assembly.One important way to take advantage of the day-night temperature cycle would be with night-time cooling: install an efficient whole-house exhaust fan to move hot air out and cool air in.I do like Martin’s suggestion of adding as much top-side rigid insulation as possible/economically feasible. Better bang for the buck and per inch of additional roof assembly profile. Something like this GBA detail for an exterior roof insulation retrofit.last_img

Leave a Reply

Your email address will not be published. Required fields are marked *